A door-and-credential inventory for a small commercial property is two linked lists: one of every opening, and one of every credential, meaning keys, cards, fobs, and codes. You build it by walking the property door by door, and a simple spreadsheet is enough. The link between the lists is the useful part, because it shows who can open what. Build it before any hardware or access control decision.
Two lists, and why the link matters
The openings list describes the doors. The credentials list describes everything that opens them. Neither one alone answers the real question, which is who can get through which door. That answer comes from the link: each credential names the doors it opens, so you can look up any door and see every credential that works on it.
Build both lists from what you can see and confirm on site. Old binders and memory help later as a cross-check, not as the starting point.
Set the boundary and the owner before you walk
Decide what counts as an opening before you start. For most small properties that means exterior entries, stairwell doors, storage and utility rooms, roof or service entries, and any interior door with a lock or reader. A door with no lock still goes on the list, marked unsecured, so nobody later wonders whether it was missed.
Door names need settling too. A short code built from floor and position, such as 1-E1 for the first exterior door on the ground floor, holds up better than labels like 'back door', which mean different things to different people. Matching those codes to labels in existing software and plans is a separate job. For now, mark the codes on a floor plan or a hand sketch as you go.
One person should own the record. Others can feed it information, but one person keeps the current version. Without an owner, the inventory drifts back into scattered notes.
What to record at each door
Walk in a fixed order, floor by floor, and fill in one row per opening:
- Door code and plain location
- Purpose: who normally uses the door and why
- Door type: single or double, glass or solid, swinging or sliding
- How it is secured: key cylinder, keypad, card reader, buzzer or intercom release, or a mix
- Whether it has an automatic operator, the powered opener started by a push plate or button
- Visible condition, such as a door that slams, drifts open, or fails to latch
- Anything you cannot confirm, written as unknown
The unknown field matters more than it looks. If you cannot tell whether a card reader is working or which key fits a cylinder, write 'unknown' instead of guessing. A guess recorded as fact sends a provider to the wrong door and hides the openings that need attention.
Photograph each door from both sides, plus a close shot of the lock or reader, and name each photo with the door code.
Building the credentials list
Record credentials by holder, one row per person or company per credential. Each row shows who holds it, what kind it is (key, card or fob, PIN code, intercom or buzzer access), which door codes it opens, and when it was issued or last confirmed. If a key carries a stamped number or tag, record that too.
Then look for the holders people forget: cleaning crews, maintenance vendors, delivery drivers given a code, former tenants, and former staff who kept a key. The spare key in a desk drawer counts. So does a code everyone shares.
Because every row lists door codes, sorting the sheet by door shows every credential that opens that door. That sort is your cross-reference.
Reconcile, rank the gaps, and keep it current
Compare the two lists. Three kinds of gaps usually turn up: doors with no known credential holder, credentials with no known door, and hardware marked unknown. Turn each gap into an open question, then rank the questions by what the door protects. An exterior entry opened by an unaccounted key comes before a supply closet with a worn latch.
Tie updates to events rather than the calendar. A person joins or leaves, a vendor changes, a lock or reader is replaced, a code is reset: each event is a trigger, and the change is not finished until the record owner has it. Reviewing an older record for stale users is a different task from this first build.
What to hand a provider before an assessment
A provider scoping access control, door hardware, intercom, or operator work can do more with a prepared package. Put together both lists, the floor plan with door codes marked, the named photos, your ranked open questions, and a few sentences on the goal, such as replacing keys on exterior doors or adding readers.
Atlas Integrated Security works with commercial properties in New York City on access control, commercial door hardware and smart locks, intercom and buzzer systems, and ADA door operators. Once your package is together, call (347) 357-0985 to talk through what you found.
Frequently asked questions
Should the inventory include doors that currently use only a mechanical key?
Yes. Key-only doors belong in a door-and-credential inventory because keys are often the hardest credentials to account for. A key can be copied or kept after someone leaves, and nothing records when it is used. Listing key-only doors and every known key holder shows where access is least visible.
What is the safest way to store a door and credential inventory?
A door and credential inventory is effectively a map of how to get into the building, so handle it like a master key. Keep one current copy with access limited to the record owner and a backup person. Keep actual PIN digits out of the main sheet and note only that a code exists and who manages it.
Do shared PIN codes belong in the credential list?
Yes. A shared PIN code is a credential like any key or card. Give it its own row with the doors it opens and the person who manages it. Nobody can say exactly who knows a shared code, so mark it as shared and record an estimated number of holders, labeled as an estimate, instead of leaving it off.
Can I build the inventory myself, or do I need a provider to walk the property?
An owner, property manager, or facility lead can build a door and credential inventory without a provider, using a floor plan, a phone camera, and a spreadsheet. The walk-through needs access to every opening. Hardware you cannot identify gets marked unknown so a provider can look at it during a later assessment.