Atlas Integrated Security supplies and installs commercial door hardware for office buildings, multifamily residential properties, retail spaces, schools, and healthcare facilities across New York City and the surrounding metro. Every project starts with a site assessment. We identify the door type, frame condition, traffic volume, fire rating requirements, and access control integration points before specifying a single piece of hardware.
What types of commercial door hardware does Atlas install?
We work across the full range of door hardware used in commercial and mixed-use buildings throughout Manhattan, Brooklyn, Queens, the Bronx, Long Island, and Northern New Jersey. That includes:
- Cylindrical and mortise locksets - standard for office suites, stairwells, and utility rooms in mid-rise and high-rise construction
- Panic hardware and exit devices - required on fire egress doors under FDNY and NYC Building Code; available in rim, mortise, and concealed vertical rod configurations
- Electric strikes and electromagnetic locks - used at controlled entry points where card readers or intercom systems must release the door
- Door closers - surface-mounted and concealed units rated for the door weight and frequency of use; required on fire-rated assemblies
- Flush bolts, coordinators, and astragals - critical components on paired-door openings common in lobbies and loading docks
- Continuous hinges and heavy-duty butt hinges - specified by door weight, material, and exposure to weather or heavy traffic
All hardware on fire-rated assemblies is selected to match the door and frame rating. We pull permits and provide documentation for DOB inspections when the scope requires it.
How does door hardware connect to a building's access control and security system?
In most commercial buildings across New York City, door hardware is not a standalone product. It is the mechanical layer of a larger security architecture. Electric strikes, mag-locks, and electrified mortise locks receive signals from access control panels. When a credential is accepted at a reader, the panel signals the hardware to release. When the door is forced or held open too long, the panel triggers an alarm.
Atlas engineers this integration from the hardware outward. We verify that the door prep - the cutout geometry, voltage requirements, and backset dimensions - matches the chosen hardware before installation begins. We confirm that the power supply and wiring infrastructure can support the hardware under full load. On retrofit projects in older Manhattan office towers or Brooklyn industrial conversions, we frequently find that existing conduit runs and panel capacity need to be upgraded before new electrified hardware will perform reliably.
We also configure door position switches and request-to-exit devices so your video surveillance and access control platforms receive accurate, real-time status data for every opening.
What compliance requirements apply to commercial door hardware in NYC buildings?
New York City imposes multiple overlapping requirements on commercial door hardware. Getting this wrong creates liability exposure for building owners and property managers.
Key compliance points include:
- ADA Title III and NYC Human Rights Law - public-facing doors must meet force and clearance requirements. Power-operated door operators are often the right solution on high-traffic accessible routes. Atlas installs low-energy and full-power ADA door operators as part of our door hardware scope.
- FDNY egress requirements - exit devices on fire doors must allow free egress without a key or special knowledge. Hardware on fire-rated assemblies must carry the appropriate listing label and must not be modified in the field.
- NYC Local Law compliance - certain local laws governing building safety and accessibility affect door hardware specifications, particularly in buildings undergoing renovation or change of occupancy.
- DOB permit requirements - hardware replacements on fire-rated openings or changes to door assembly configurations typically require a permit and inspection under the NYC Building Code.
Atlas documents every hardware selection against the applicable code before work begins. We work alongside your architect or expediters when permit drawings are required.
If your building has deferred door hardware maintenance, aging exit devices, or hardware that no longer integrates cleanly with your access control system, call Atlas Integrated Security at (347) 357-0985 to schedule a site assessment. We serve property managers and facilities directors across New York City and the surrounding metro.
Frequently asked questions
Does commercial door hardware need to comply with NYC building codes?
Yes. NYC buildings must meet DOB requirements, ADA Title III standards, and FDNY fire egress codes. Hardware on rated assemblies must be listed and labeled accordingly. Atlas handles compliance documentation as part of every project.
Can you integrate new door hardware with our existing access control system?
Yes. Atlas selects and installs hardware that is compatible with your current credential readers, electric strikes, and control panels. We verify electrical specs and door prep before any hardware ships to the site.
How long does a commercial door hardware project take?
Scope drives the timeline. A single door replacement can be completed in a few hours. A multi-entry retrofit across a large building is typically phased over several days to keep your facility operational throughout the work.
Planning a security system for your building? Request a site assessment.